-40%
Taco 0013 BF3-J Circulating Pump
$ 158.39
- Description
- Size Guide
Description
Taco 0013 BF3-J Circulating PumpIt's perfect for boilers with high pressure drop, fan coil units, heat exchangers, large radiant heat systems and geothermal systems.
Motor on this pump is impedance-protected.
Permanently lubricated ball bearings, a nonmetallic impeller, a ceramic shaft, and no mechanical seal.
With replaceable cartridge, you don't need to replace the entire circulator.
Universal Flange-to-Flange Dimensions
Description
Product Description
Taco 0013-BF3-J Circulator Pump
is designed for use in high head and high flow applications in larger residential and light commercial systems. The Taco 0013-BF3-J circulator is perfect for boilers with high pressure drop, fan coil units, heat exchangers, large radiant heat systems and geothermal systems. Universal flange to flange dimensions and flange orientation allow allows the Taco 0013-BF3-J circulator to replace many other models. This model is compact, features low power consumption and ideal for high-efficiency jobs.
***Rubber gaskets included with pump***
Typical Applications
High Pressure Drop Boilers
Medium/Large Hydronic, Geothermal and Radiant Heating projects
Wood Boilers / Furnaces
Hydro-Air Fan Coils
Open Loop systems like Outdoor Wood Furnaces
Performance Data
Flow Range: 0-34 GPM
Head Range: 0-33 Feet
Maximum Fluid Temperature: 230 degrees F (110 degrees C)
Horse Power: 1/6
Working pressure: 125 PSI
Connection Sizes: 3/4", 1", 1-1/4", 1-1/2" Flanged
Features
High Velocity Performance-Compact Design
Universal Flange to Flange Dimensions
Direct Drive-Low Power Consumption, Quiet, Efficient Operation
Unique Replaceable Cartridge Design-Field Serviceable
Unmatched Reliability-Maintenance Free
Specifications
Item
Circulator Pump
Type
Hot Water
HP
1/6
Phase
1
Voltage
115
Amps
2.00
Inlet/Outlet
Flanged
Housing Material
Cast Iron
Face to Face Dimension (In.)
6-1/2
Max. Temp. (F)
230
Max. Working Pressure (PSI)
125
Flange/Union Included
No
Shut-Off (Ft.)
34
Impeller Material
Polypropylene
Thermal Protection
Impedance
GPM of Water @ 1 Ft. of Head
29
GPM of Water @ 2 Ft. of Head
28.5
GPM of Water @ 3 Ft. of Head
28
GPM of Water @ 4 Ft. of Head
27.5
GPM of Water @ 5 Ft. of Head
27.25
GPM of Water @ 6 Ft. of Head
27
GPM of Water @ 7 Ft. of Head
26.5
GPM of Water @ 8 Ft. of Head
26
GPM of Water @ 9 Ft. of Head
25.5
GPM of Water @ 10 Ft. of Head
24.5
GPM of Water @ 15 Ft. of Head
22
GPM of Water @ 20 Ft. of Head
18
GPM of Water @ 25 Ft. of Head
12
GPM of Water @ 30 Ft. of Head
5
Length (In.)
7-3/4
Width (In.)
6
Max. GPM @ Head (Ft.)
29 @ 1
Best Efficiency GPM @ Head (Ft.)
20 @ 17
Min. GPM @ Head (Ft.)
5 @ 30
Drive Type
Direct
Construction
30 Percentage Glass-filled Polyether Sulfone
FPT (In.)
3/4
Weight
13.00
Video
Outdoor wood boiler maintenance
Video will open in a new window
Using the mobile app? Copy this link into your browser: